News

 
  1. Public Holiday and Changed Opening Hours

    16 May 12 Between 17–18 May RTI Headquarter is closed.
    RTI Inc is open as usual.

  2. New Software Release – 2012.05A

    11 May 12 Piranha and Barracuda Latest Update

    Released: May 11, 2012

    Ocean: 2012.05.09.82
    QABrowser: 4.2B
    oRTIgo: 6.5A
    CT Dose Profile Analyzer: 4.1A
    Firmware: 2012.2A

  3. Mammo12

    One Shot HVL for Mammography

    07 May 12 One shot HVL for mammography is now available to all new Piranhas of version 2 or higher.
    One shot HVL is possible both if you are using Ocean or QA Browser, with or without compression paddle.

    All Piranhas (version 2 or higher), which are in for re-calibration, will get the one shot HVL feature.

  4. Time for Calibration - Schedule Yours Now

    06 May 12 Please take five minutes to schedule your coming calibration with the RTI Service department.

Show all news
Detector Extender

Piranha Dose Probe

Piranha Dose Probe

For Low dose Rate Measurements with the Piranha

The Piranha Dose Probe is specially designed for low dose rate measurements with the Piranha. The detector is small to minimize interference with the X-ray systems’ AEC. The Piranha Dose Probe is ideal for field service situations since the detector is well protected from damages by the metal housing. Since it is a solid-state detector, it needs no corrections for temperature or pressure, or bias voltage.

Fluoroscopy

The Piranha Dose Probe is small and has a fast response which makes it ideal for pulsed fluroscopy. It can detect the individual pulses, determine pulse rate and show waveforms even at the highest pulse rates used on modern fluoroscopy systems and be used both for continuous and pulsed fluroroscopy. This is not possible with ionization chambers since their response is too slow to resolve individual pulses.

The Piranha Dose Probe supports the Piranha ADI (automatic detector identification) system. All information about the probe is stored in a memory inside the probe. When connected, the Piranha automatically identifies the probe and makes all necessary adjustments without any need for interaction from the user. The Piranha ADI system also gives full interchangeability of probes between different Piranha systems using the same type of probes.


 

 

 

 

 

 

 

Beam quality - W/3 mm A

Specifications
Type  R100B
Sensitivity  55 µC/Gy
Size  20 x 45 x 7.4 mm, 0.79" x 1.8" x 0.29"

Weight 85 g (3 oz)
Active detector area 10 x 10 mm, 0.39" x 0.39"
Cable length 2.0 m (6.6 ft)
Connector  Piranha type with automatic detector identification
Dose range  0.1 nGy - >1.5 kGy

12 nR - >170 kR
Dose rate range  1 nGy/s - 76 mGy/s

0.4 mR/h - 31 kR/h
Dose per pulse  1 nGy/pulse - 3 kGy/pulse

120 nR/pulse - 340 kR/pulse
Backscatter
None

Article Nr: 9730003-00

 
 

Please enter your user name and password below.