News

 
  1. RTI Electronics AB is Looking for New Employees

    26 Jan 12 Would you like to be part of developing the medical technology products and markets of the future? RTI Electronics is growing and is now looking for new co-workers who want to be part of shaping the future in an exciting industry.

  2. RTI Electronics, Inc. has Moved

    02 Jan 12 RTI Electronics, Inc. has moved to larger location with lots of space to grow. Starting Tuesday, January 3, 2012 you can find RTI Electronics, Inc. at:

    33 Jacksonville Road
    Building 1
    Towaco, NJ 07082

    RTI Inc's phone numbers and contact information are the same for your convenience.

  3. Merry Christmas 2011 from RTI

    All the Best for 2012

    22 Dec 11 We wish to thank our customers and users for a fruitful 2011, wish you a really nice Christmas, and the best for 2012. Monday 26 December RTI Headquarters is closed.

  4. Ocean-Central-nov-2011webb-2.jpg

    Awaited RTI’s Ocean Central is Here

    07 Dec 11 Ocean Central makes it possible to tie all Ocean users together via network and internet. With Ocean Central you can save all measured data in one place and easily distribute templates to all users.

Show all news

Solidose 400

Solidose 400

Flexible and User-friendly Dosimeter with that Little Extra

Solidose is RTI's user-friendly dosimeter and rate meter that is used for the quality control and servicing of X-ray equipment. The Solidose 400 contains built-in applications so that measurements can be performed as simply as possible, and is the Solidose that can be used together with ion chambers. Solidose 400 does not automatically contain any calibration modules, instead you have the complete freedom to select those which meet your needs, together with an external probe, ion chamber, or both. Solidose 400 comes with WinRAD.

Reduced Solidose Price

Right now, we offer discounted prices on our popular Solidose meters. Contact your local distributor to get more information or to place an order.


Main Features

Dose and dose rate
Radiography
CT
Mammography
Input dose rate to image intensifier
Reproducibility
HVL
Relative mAs
Dose/frame
Ratio

Optional calibrations (ADI)
8/A   For heavy filtred beams, for example input dose to the I.I. Reference point at 70 kV/23 mm Al.
8/B   For standard radiography. Reference point at 70 kV/3 mm Al.
8/C   For film dose mammography. Reference point at 28 kV/2 mm Al + 30 µm Mo.
8/D   For skin dose mammography. Reference point at 28 kV/30 µm Mo.

Details
  • A single measuring range covering more than six decades (>120 dB).
  • Built-in applications such as HVL and reproducibility.
  • Automatic Detector Identification (ADI) system, fully compatible with PMX-III. 
  • RS-232 computer interface with software (WinRAD).
  • Battery operated or external power supply.
  • Possible to connect other solid state detectors from RTI, using ADI system.
  • Can be used together with BNC/Banana type ion chambers.
  • Use of solid state detectors as well as ion chambers.
  • Bias voltage is adjustable by the user (keypad), 100 - 300 V.
  • Ion chamber adapter, female BNT bayonet triaxial.

Specifications
Charge Range 0.5 pC-10 mC
Inaccuracy ±1 % or ±0.5 pC
Current  Range 5 pA-15 µA
Inaccuracy ± 1% or ±0.5 pA
Dose (R100)   Range 10 nGy-200 Gy
1.15 µR-23 000 R
Inaccuracy ±5 %
Dose rate (R100)  Ranges 100 nGy/s-300 mGy/
11.5 µR/s-34.5 R/s
Inaccuracy ±5 %
Random error  ±1 % 
Bias voltage  75-315 V
Display  Alpha-numerical 16x2 LCD
Connector  Trial LEMO type "0"
Computer interface  RS-232
Dimensions  205x135x58 mm
Weight  1.1 kg
Power source  4 power alkaline batteries type LR6 (size AA)
Battery life  20 hours
Power supply  HP F1011A (optional)

 

 
 